Hi
Greg,
Yes the interface is a single lambda and then there should be a DWDM Line system
or could be as you said a RODAM. Great mind
have similar thought J J BR Diego From: Greg Bernstein [mailto:gregb@grotto-networking.com] Hi Diego, looks like we've been thinking about similar
issues lately.
I’ve a doubt about how to model the following situation.
+-----------------+
|
|-------+
|
| OEO |
| Lambda |-------+
| Switch |
|
|
|
|
+-----------------+
The node itself is able to
cross connect only the Lambda while the interface has a OEO transponder that is
able to change the lambda frequency. In this case there are two different
‘switching capability’ the spatial one that is performed by the
switch (lambda 1, port A) --> (lambda1, port B) and the frequency switching
is done by the OEO transponder. Witch kind of interface switching
capability I have to advertise? BR
Diego Caviglia Product PA Broadband BNET Marconi S.p.A Ericsson Global Via Anagnina,203 0018, Roma , Italy Office: +39 010 600 3736 Fax: +39 010 600 3493 Mobile: +39 335 7181762 Email: diego.caviglia@ericsson.com This communication is
confidential and intended solely for the addressee(s). Any unauthorized review,
use, disclosure or distribution is prohibited. If you believe this message has
been sent to you in error, please notify the sender by replying to this
transmission and delete the message without disclosing it. Thank you.
-- ===================================================Dr Greg Bernstein, Grotto Networking (510) 573-2237 |