[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Question on Restart Procedure - Restart Time
Hi Suresh,
In the GMPLS RSVP-TE document, Section 9.3, first paragraph, last sentence:
A node MAY wait longer based on local policy or configuration information.
Is this what you are looking for?
Zhi
Suresh Katukam wrote:
>
>> Ping and others,
>>
>> Is it possible to define an infinite value for Restart time so that
>> one may not
>> have to remove circuits as soon as Restart timer expires? This is
>> more valid
>> in SONET/SDH cases where a control channel may be down for a long enough
>> time that is difficult to guess it up front..
>>
>> In SONET/SDH cases, nodes should delete circuits in these conditions
>>
>> - explicitly removed by customer
>> - Recovery Timer expires
>>
>> other conditions ( restart timer expires, soft-state time out )
>> should be given
>> optional. there should be values or procedures defined in these other
>> cases
>> such that the node does not remove LSPs.
>>
>> Thanks,
>> Suresh
>
>
>