Hi,
1. The ConfigNack Object has the Config object inclusion in the Nack
message as optional.[<CONFIG>]. This will be mandatory right, since
there is no error code, when a Nack arrives, for a negotiable Config
or non-negotiable Config, the Config Object MUST be included and hence
mandatory.
2. Some paragraphs of section 13.4.3 still speaks about the error
code. Hope missed out while editing.
3. Already mentioned about similarities with OIF UNI 1.0. There it is
mentioned CCID == InterfaceID in in-fiber case. This draft also speaks
about in-fiber case in Section 3. According to this draft, CCID is a
32 bit number and Interface ID can be 32 bit( IPv4 or unnumbered ) or
128 bit
( IPv6 ). OIF UNI is mentioning to refer IETF LMP for message
formats. So how can a 32 bit number be matched with a 128bit number?
Is this question is meaningful or am i missing something? Since OIF
UNI is mentioning IETF LMP for message formats am cross posting in
this list. Kindly clarify me in this regard.
Thanks,
Ramesh