[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: LMP



Bert,

> -----Original Message-----
> From: Wijnen, Bert (Bert) [mailto:bwijnen@lucent.com]
> Sent: Tuesday, February 26, 2002 2:26 PM
> To: ccamp-wg
> Subject: LMP
> 
> 
> 
> When I look at section 14, then I wonder:
> 
>   LOCAL_CCID:  Class = 1, C-Type = 1, 4 byte CC_id
>   REMOTE_CCID: Class = 2, C-Type = 1, 4 byte CC_id
> 
> Why is that not:
> 
>   CCID: Class = 1, LOCAL: C-Type = 1, 4 byte CC_id
>   CCID: Class = 1, LOCAL: C-Type = 2, 4 byte CC_id
This change is fine with me unless there is objection from others.

Thanks,
Jonathan

> 
> The above is just an example. this is type of definitions
> occur throughout section 14, and it seems we are using
> many more name space code points than really needed. 
> Is this handy? Wise? Good design?
> 
> Bert 
>